Providing resilient power protection strategies for over 10 years.
Secure Power is a single point of contact for all aspects of critical power infrastructure.
kVA: 80kVA
Watts: 72000
The Master MPS series offers optimal power quality and protection for mission-critical loads, such as data centres, industrial processes, telecommunications, security, and electro-medical equipment. The UPS offers online double-conversion technology (VFI SS 111-IEC EN 62040-3) and an isolated...
The Master MPS series offers optimal power quality and protection for mission-critical loads, such as data centres, industrial processes, telecommunications, security, and electro-medical equipment. The UPS offers online double-conversion technology (VFI SS 111-IEC EN 62040-3) and an isolated transformer inverter. The range comprises versions with three-phase input and single-phase output from 10 to 100 kVA, as well as versions with three-phase input and output from 10 to 200 kVA.
All variants include a thyristor-based 6-pulse rectifier, with or without optional harmonic filters. On request, a 12-pulse thyristor-based rectifier is available for the 60 kVA and 80 kVA models, with or without optional harmonic filters.
Powering the UPS from generator sets and MT/BT transformers is easier and more efficient by minimising power loss in the system and coils, correcting the power factor, and eliminating current harmonics caused by the UPS-supplied loads. In addition, the gradual rectifier startup (power walk-in) and the ability to limit battery charging currents reduce the input current consumption. This lowers the load on the source, which is especially helpful if the source is a generator set.
Please Note: All images are for illustrative purposes only
Manufacturer | Riello |
Topology | Online Double-Conversion |
VA | 80000 |
Watt | 72000 |
Output Voltage | 380-415V |
Input Frequency | 50/60 Hz autoselect |
Output Frequency | 50/60Hz +/–0.1 % (autosensing) |
Communications Ports | UPS status led bar - Graphic touch screen diplay - 2 slots for communications interface USB - RS232 - Contact interface with 5x opto insulated Input and 4x Output relays |
Operating Temperature | 0 to 40°C |
Certification | IEC/EN 62040-1, IEC/EN 62040-2, CE, IEC/EN 62040-3, RoHS compliant, L V 2014/35/EU, EMC 2014/30/EU |
All UPS solutions require proactive maintenance to not only guarantee the lifespan of the backup power system but to also ensure that it is in optimal operational condition at all times. Secure Power offers a comprehensive range of UPS maintenance services and our team of nationwide engineers are available 24/7, 365 days a year to carry out all routine and emergency works. We have a range of standard UPS maintenance contract packages and also provide tailored solutions to fit any requirement. Below is a snapshot of what our contracts offer.
Service | Bronze | Silver | Gold | Platinum |
---|---|---|---|---|
Response Time | Next Business Day | Next Business Day | 8hrs | 4hrs |
Discounted travel and labour costs | N/A | N/A | N/A | |
24/7 Technical support | ||||
Temporary UPS in the event of a failure (up to 10kVA single phase) | ||||
1 preventative maintenance visit per year | - | |||
Travel & Labour costs for reactive maintenance | - | |||
Professional service report | - | |||
Emergency callout number | - | |||
Discounted parts | - | - | ||
Access to UK wide spares network | - | - |